Menü
vissza
  1. Termékek
  2. Automation technology - Sensors and actuators
  3. M12-A
  4. M12 Square male panel mount connector, Contacts: 4, unshielded, single wires, IP69k, IP68, IP67, UL 2238, M3 (4x), Front mounting, Square housing 26 mm, Positionable coding alignment
Cikkszám: 99 3433 116 04

M12 Square male panel mount connector, Contacts: 4, unshielded, single wires, IP69k, IP68, IP67, UL 2238, M3 (4x), Front mounting, Square housing 26 mm, Positionable coding alignment

M12-A, series 763, Automation Technology - Sensors and Actuators

Elérhető Pólusszámok
Hasonlítsa össze a terméket
Letöltések
Általános jellemzők
továbbkevesebb
Alkatrész sz. 99 3433 116 04
Csatlakozó kialakítása Square male panel mount connector
Szabványos típus DIN EN 61076-2-101
Programmazione A-coded
Vezeték hossza 0.2 m (Standard 0.2 m. Other lengths are available on request).
Verzió Connector pin straight
Rögzítés módja screw
Csatlakoztatás típusa single wires
Védelmi szint IP69k, IP68, IP67
Csatlakozási keresztmetszet 0.25 mm² / AWG 24
Hőmérséklet tartomány tól/ig -40 °C / 85 °C
Mechanikus élettartam > 100 Mating cycles
Tömeg (gr) 24.78
Vámtarifaszám 85369010
Származási ország DE
Névleges feszültség 250 V
Névleges impulzusfeszültség 2500 V
Névleges áramerősség 4 A (3 A UL)
Szennyezettségi fok 3
Túlfeszültség kategória II
Anyagcsoport II
EMV megfelelőség unshielded
A ház anyaga CuZn (Brass nickel plated)
Az érintkező test anyaga PA black
Érintkező anyaga CuZn (brass)
Érintkező bevonat Au (gold)
REACH SVHC CAS 7439-92-1 (Lead)
Jelen lévő PFAS a0fdf92d-11e0-47d2-803f-42398ec24e5a
Tanúsítások UL 2238
Copper (9903.78.01) 0.001764 kg
Biztonsági figyelmeztetések
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. To protect against unintentional opening of the connector, the thread between the housing and the connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with voltages dangerous to the touch. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
  4. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  5. The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
  6. Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
  7. Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".
  8. To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
  9. The protection class specification applies on condition that the four mounting holes are made as blind holes.