Menu
Back
  1. Products
  2. Automation technology - Sensors and actuators
  3. M12-A
  4. M12 Male panel mount connector, Contacts: 8, unshielded, single wires, IP68, M12x1.0, front fastened
Part no.: 76 1031 1011 00008-0200

M12 Male panel mount connector, Contacts: 8, unshielded, single wires, IP68, M12x1.0, front fastened

M12-A, series 763, Automation Technology - Sensors and Actuators
Available numbers of contacts
Compare product
Downloads
General features
Moreless
Part no. 76 1031 1011 00008-0200
Connector design Male panel mount connector
Wire length 0.2 m
Version Panel mount Connectors
Connector locking system screw
Termination single wires
Degree of protection IP68
Cross-sectional area 0.25 mm² / AWG 24
Temperature range from/to -40 °C / 85 °C
Mechanical operation > 100 Mating cycles
Weight (g) 15.65
Customs tariff number 85369010
Country of Origin DE
Rated voltage 30 V
Rated impulse voltage 800 V
Rated current 2.0 A
Insulation resistance > 108 Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance unshielded
Voltage 650 V DC
Housing material CuZn (Brass nickel plated)
Contact body material PA
Contact material CuZn (brass)
Contact plating Au (gold)
REACH SVHC CAS 7439-92-1 (Lead)
SCIP number 638fd8a8-f252-4160-8082-5ca988743def
Security notices
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  4. To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
  5. The protection class specification applies on condition that the four mounting holes are made as blind holes.
M12-A
76 1031 1011 00008-0200