  4. M12 Male panel mount connector, Contacts: 4, unshielded, THR, IP68, UL 2238, M16x1.5, Front mounting
Cikkszám: 86 0243 0000 00044

M12 Male panel mount connector, Contacts: 4, unshielded, THR, IP68, UL 2238, M16x1.5, Front mounting

M12-L, series 823, Automation Technology - Voltage and Power Supply

Hasonlítsa össze a terméket
Letöltések
Általános jellemzők
továbbkevesebb
Alkatrész sz. 86 0243 0000 00044
Csatlakozó kialakítása Male panel mount connector
Programmazione L-coded
Verzió Connector pin straight
Rögzítés módja screw
Csatlakoztatás típusa THR
Védelmi szint IP68
Csatlakozási keresztmetszet max. 1.50 mm² with ferrule / max. 2.50 mm² without ferrule / AWG 16 with wire-end ferrule / AWG 14 without wire-end ferrule
Hőmérséklet tartomány tól/ig -40 °C / 105 °C
Mechanikus élettartam > 100 Mating cycles
Tömeg (gr) 9.65
Vámtarifaszám 85369010
Névleges feszültség 63 V
Névleges impulzusfeszültség 1500 V
Névleges áramerősség 16.0 A
Szigetelési ellenállás > 10¹0 Ω
Szennyezettségi fok 3
Túlfeszültség kategória III
Anyagcsoport I
EMV megfelelőség unshielded
Az érintkező test anyaga PA
Érintkező anyaga CuZn (brass)
Érintkező bevonat Au (gold)
Záró anyag Zinc die-cast nickel-plated
REACH SVHC CAS 7439-92-1 (Lead)
Jelen lévő PFAS b453210e-0b86-4ed4-a8f0-773386bd1a86
Tanúsítások UL 2238
Kisfeszültségű irányelv EN 60529:1991
RoHS irányelv EN IEC 63000:2018
Biztonsági figyelmeztetések
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  4. The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
  5. Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
  6. Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".
  7. To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).