Číslo položky: 09 0198 00 24
M16 Female panel mount connector, Contacts: 24, unshielded, solder, IP40, M18x0,75, Front mounting
M16 IP40, series 680, Miniature Connectors
Existuje novější verze tohoto článku
Přímé srovnání stará/nová verze
09 0498 00 24
M16 Female panel mount connector, Contacts: 24, unshielded, solder, IP67, UL 2238, M18x0,75, Front mounting
M16 IP67, series 723, Miniature Connectors
Obecné vlastnosti
víceméně| Díl č. | 09 0198 00 24 |
| Konstrukce konektoru | Female panel mount connector |
| Provedení | Connector socket straight |
| Uzamykací systém konektorů | screw |
| Ukončení | solder |
| Stupeň ochrany 1 | IP40 |
| Průřez přípojky | 0.14 mm² / AWG 26 |
| Rozsah teplot od/do | -40 °C / 85 °C |
| Mechanický provoz | > 500 Mating cycles |
| Hmotnost (gr) | 9.45 |
| Číslo celního sazebníku | 85369010 |
| Země původu | DE |
Elektrické parametry
víceméně| Jmenovité napětí | 60 V |
| Jmenovité impulzní napětí | 500 V |
| Jmenovitý proud | 1.0 A |
| Izolační odpor | ≥ 10¹0 Ω |
| Stupeň znečištění | 1 |
| Kategorie přepětí | I |
| Skupina materiálů | III |
| Soulad s EMV | unshielded |
Materiál
víceméně| Materiál pouzdra | Zinc die-cast nickel-plated |
| Materiál kontaktního tělesa | PBT (UL94 V-0) |
| Materiál kontaktu | CuSn (bronze) |
| Pokovení kontaktů | Au (gold) |
| REACH SVHC |
CAS 7439-92-1 (Lead) |
| SCIP číslo | 75a31342-7234-43f5-95c3-275dfd059caa |
Klasifikace
víceméně| eCl@ss 11.1 | 27-44-01-09 |
| ETIM 9.0 | EC003569 |
Trade-Compliance
víceméně| Copper (9903.78.01) | 0.005570 kg |
Bezpečnostní upozornění
- The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
- The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
- Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
- The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
- Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".
- To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
Stahování
Datový list
Datový list 09 0198 00 24
stáhnout
REACH
09 0198 00 24
stáhnout
RoHS
09 0198 00 24
stáhnout
China RoHS
09 0198 00 24
stáhnout
EPLAN数据
09 0198 00 24
stáhnout
Ověření pro stažení
Pro pokračování stažení CAD dokončete prosím ověření.
Soubory CAD
Vyberte požadovaný formát