Menu
Back

Male cable connector, CAN-Bus

M12-A, Male cable connector, CAN-Bus, Series

Ordering no:

Male cable connector, CAN-Bus

Male cable connector, CAN-Bus, Series 763
Available numbers of contacts
Compare product
77 2529 0000 50705-0200
M12-A male cable connector, Contacts: 5, shielded, moulded on cable, IP67, UL listed, PUR purple, 1 x 2 x AWG22 / 1 x 2 x AWG24
M12, series 763, Automation technology - sensors and actuators
General features
Moreless
Order number 77 2529 0000 50705-0200
Connector design male cable connector
Version connector male straight
Connector locking system screw
Termination moulded on cable
Degree of protection IP67
Cross-sectional area 1x2xAWG 22 / 1x2xAWG 24 / 1x2x AWG 22 / 1x2x AWG 24
Temperature range from/to -25 °C / 85 °C
Mechanical operation > 100 Mating cycles
Weight (g) 720
Customs tariff number 85444290
Rated voltage 60 V
Rated impulse voltage 1500 V
Rated current (40 °C) 4 A
Insulation resistance ≥ 10¹⁰ Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance shielded
Housing material PUR
Contact body material PUR
Contact material CuZn (brass)
Contact plating Au (gold)
Locking material CuZn (Brass nicke,l plated)
REACH SVHC CAS 7439-92-1 (Lead)
Cable data
Moreless
Cable length 2 m
Sheath material PUR
Single-lead insulation Polyolefine und hautgeschäumtes PE
Halogen free Yes
Cable color purple
Cable diameter 7.2 mm
Single-lead structure 19x0.16 und 19x0.13 mm
Temperature range cable in move from/to -20°C / +80°C
Temperature range cable fixed from/to -40°C / +80°C
Bending radius, fixed cable 5 x Ø
Bending radius, moving cable 10 x Ø
Bending cycles 1 Mio.
Permitted acceleration max. 5 m/s²
UL style 2 AWM444
Approval 1 UL listed
Low Voltage Directive 2014/35/EU (EN 60529:1991;EN 60204-1:2018)
RoHS Directive 2011/65/EU (EN 50581:2012)
77 2529 0000 50705-0500
M12-A male cable connector, Contacts: 5, shielded, moulded on cable, IP67, UL listed, PUR purple, 1 x 2 x AWG22 / 1 x 2 x AWG24
M12, series 763, Automation technology - sensors and actuators
General features
Moreless
Order number 77 2529 0000 50705-0500
Connector design male cable connector
Version connector male straight
Connector locking system screw
Termination moulded on cable
Degree of protection IP67
Cross-sectional area 1x2xAWG 22 / 1x2xAWG 24 / 1x2x AWG 22 / 1x2x AWG 24
Temperature range from/to -25 °C / 85 °C
Mechanical operation > 100 Mating cycles
Weight (g) 720
Customs tariff number 85444290
Rated voltage 60 V
Rated impulse voltage 1500 V
Rated current (40 °C) 4 A
Insulation resistance ≥ 10¹⁰ Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance shielded
Housing material PUR
Contact body material PUR
Contact material CuZn (brass)
Contact plating Au (gold)
Locking material CuZn (Brass nicke,l plated)
REACH SVHC CAS 7439-92-1 (Lead)
Cable data
Moreless
Cable length 5 m
Sheath material PUR
Single-lead insulation Polyolefine und hautgeschäumtes PE
Halogen free Yes
Cable color purple
Cable diameter 7.2 mm
Single-lead structure 19x0.16 und 19x0.13 mm
Temperature range cable in move from/to -20°C / +80°C
Temperature range cable fixed from/to -40°C / +80°C
Bending radius, fixed cable 5 x Ø
Bending radius, moving cable 10 x Ø
Bending cycles 1 Mio.
Permitted acceleration max. 5 m/s²
UL style 2 AWM444
Approval 1 UL listed
Low Voltage Directive 2014/35/EU (EN 60529:1991;EN 60204-1:2018)
RoHS Directive 2011/65/EU (EN 50581:2012)
77 2529 0000 50705-1000
M12-A male cable connector, Contacts: 5, shielded, moulded on cable, IP67, UL listed, PUR purple, 1 x 2 x AWG22 / 1 x 2 x AWG24
M12, series 763, Automation technology - sensors and actuators
General features
Moreless
Order number 77 2529 0000 50705-1000
Connector design male cable connector
Version connector male straight
Connector locking system screw
Termination moulded on cable
Degree of protection IP67
Cross-sectional area 1x2xAWG 22 / 1x2xAWG 24 / 1x2x AWG 22 / 1x2x AWG 24
Temperature range from/to -25 °C / 85 °C
Mechanical operation > 100 Mating cycles
Weight (g) 720
Customs tariff number 85444290
Rated voltage 60 V
Rated impulse voltage 1500 V
Rated current (40 °C) 4 A
Insulation resistance ≥ 10¹⁰ Ω
Pollution degree 3
Overvoltage category II
Insulating material group II
EMC compliance shielded
Housing material PUR
Contact body material PUR
Contact material CuZn (brass)
Contact plating Au (gold)
Locking material CuZn (Brass nicke,l plated)
REACH SVHC CAS 7439-92-1 (Lead)
Cable data
Moreless
Cable length 10 m
Sheath material PUR
Single-lead insulation Polyolefine und hautgeschäumtes PE
Halogen free Yes
Cable color purple
Cable diameter 7.2 mm
Single-lead structure 19x0.16 und 19x0.13 mm
Temperature range cable in move from/to -20°C / +80°C
Temperature range cable fixed from/to -40°C / +80°C
Bending radius, fixed cable 5 x Ø
Bending radius, moving cable 10 x Ø
Bending cycles 1 Mio.
Permitted acceleration max. 5 m/s²
UL style 2 AWM444
Approval 1 UL listed
Low Voltage Directive 2014/35/EU (EN 60529:1991;EN 60204-1:2018)
RoHS Directive 2011/65/EU (EN 50581:2012)
Do you have questions regarding our products, cannot find a specific model or would like to receive a personalised offer? If so, select your country and postcode to find the appropriate contact person.
Male cable connector, CAN-Bus
Ordering no77 2529 0000 50705-0200
Male cable connector, CAN-Bus
Ordering no77 2529 0000 50705-0500
Male cable connector, CAN-Bus
Ordering no77 2529 0000 50705-1000